Magnetoplasmonics Lab

Archives October 2024

News On Plasmonics

In these days, the Journal of Scientific Reports published a new paper entitled as “Angular surface plasmon resonance‑based sensor with a silver nanocomposite layer for effective water pollution detection”

For sensing various samples of polluted water and various sodium chloride concentrations using an angular surface plasmon resonance (ASPR), we have introduced a conventional structure and a hybrid heterostructure in the current research. The suggested structures are composed of silver metal, dielectric layers, silver nanocomposite, and a sensing medium. The refectance spectra of all structures in the visible region were obtained through the utilization of the transfer matrix method by using the angular interrogation method depending on the Kretschmann confguration. Through our findings, five substrate parameters have been optimized to attain the utmost level of sensitivity across all structures: the thickness of Ag-metal, the type and thickness of dielectric materials, the host material type and the volume fraction of nanoparticles for the nanocomposite layer. In this regard, the suggested sensor provides excellent performance with a sensitivity of 448.1°/RIU, signal-to-noise ratio of 0.787, sensor resolution of 0.284°, and figure of merit of 78.766 RIU−1. Therefore, we believe that the introduced design of our ASPR sensor presents a good candidate for an accurate and effcient detection of low concentrations of contaminated water and sodium chloride as well.

News On Plasmonic Biosensors

In these days, the journal of Sensors published a new paper entitled as “New Biosensor for Determination of Neuropilin-1 with Detection by Surface Plasmon Resonance Imaging

Abstract: Neuropilin-1 is transmembrane protein with soluble isoforms. It plays a pivotal role in both physiological and pathological processes. NRP-1 is involved in the immune response, formation of neuronal circuits, angiogenesis, survival and migration of cells. The specific SPRI biosensor for the determination of neuropilin-1 was constructed using mouse monoclonal antibody that captures unbound NRP-1 form body fluids. The biosensor exhibits linearity of the analytical signal between 0.01 and 2.5 ng/mL, average precision value 4.7% and recovery between 97% and 104%. The detection limit is 0.011 ng/mL, and the limit of quantification is 0.038 ng/mL. The biosensor was validated by parallel determination of NRP-1 in serum and saliva samples using the ELISA test, with good agreement of the results.